Environmentally Friendly All-Steel Anti-Static Floor: Sustainable, Durable, and Safe for Your Business
The Environmentally Friendly All-Steel Anti-Static Floor is a modern flooring solution designed to offer both sustainability and superior protection against electrostatic discharge (ESD). Made from high-quality steel with an eco-conscious design, this floor provides optimal ESD control, enhances workplace safety, and offers durability for high-traffic environments. Perfect for industries such as data centers, electronics manufacturing, and clean rooms, this flooring solution not only ensures the safety of sensitive electronic equipment but also aligns with your company’s commitment to environmental responsibility.
In this article, we will explore the daily maintenance, installation instructions, installation conditions, and storage conditions of the Environmentally Friendly All-Steel Anti-Static Floor. By the end, you will have a comprehensive understanding of how to install, maintain, and preserve this flooring solution for long-lasting performance.
The Environmentally Friendly All-Steel Anti-Static Floor is made from recyclable steel, minimizing environmental impact while maintaining high performance and durability. This sustainable approach reduces the carbon footprint of your operations without compromising on strength or safety.
The floor’s anti-static properties ensure that static electricity is effectively dissipated, protecting sensitive electronic equipment and preventing costly damage due to electrostatic discharge. This makes it ideal for data centers, electronics production lines, and clean rooms where static control is critical.
Constructed from high-strength steel, this floor is designed to withstand heavy loads, foot traffic, and machinery without compromising its structure. It is resistant to corrosion, wear, and chemicals, making it suitable for a wide range of industries.

Proper maintenance ensures that the Environmentally Friendly All-Steel Anti-Static Floor continues to provide excellent performance over time. The following maintenance practices will help you keep the floor in optimal condition:
Keeping the floor clean is essential to maintain its anti-static properties and appearance. Dust and debris can interfere with the floor’s performance, so regular cleaning is important.
Frequency: Clean the floor daily or weekly, depending on the level of foot traffic.
Cleaning Method: Use a damp mop with a mild detergent. Avoid abrasive cleaners or chemicals that may damage the anti-static coating.
Drying: After cleaning, allow the floor to dry completely to prevent moisture buildup.
Periodically inspect the floor for signs of wear, scratches, or damage that could compromise its performance. Look for any areas where the surface may have been damaged by heavy equipment or sharp objects.
Frequency: Perform visual inspections at least once a month.
Action: If any damage is found, it is recommended to repair or replace the affected sections to maintain the floor’s integrity.
The Environmentally Friendly All-Steel Anti-Static Floor is resistant to many chemicals, but prolonged exposure to harsh chemicals could damage the surface. Always ensure that cleaning products are non-abrasive and free from solvents or acids that could affect the anti-static properties of the floor.
Before beginning the installation, ensure that the environment and the surface are properly prepared. A clean, dry, and level surface will ensure that the floor is installed correctly and performs as expected.
| Pre-Installation Task | Instructions |
|---|---|
| Surface Condition | Ensure the installation surface is clean, dry, and level. |
| Temperature Control | Maintain a room temperature between 18°C and 25°C (64°F - 77°F). |
| Humidity Control | Keep relative humidity between 30% and 60%. |
| Moisture Control | Ensure no moisture is present on the surface, as this can affect adhesion. |
The Environmentally Friendly All-Steel Anti-Static Floor uses a modular system for easy installation. Follow these steps to ensure proper installation:
Step 1: Measure the area where the floor will be installed and plan the layout of the panels.
Step 2: Begin laying the floor panels from one corner of the room, working your way toward the opposite side. Ensure that each panel fits snugly and aligns with the adjacent panels.
Step 3: Secure the panels using the recommended fasteners or adhesives. Ensure that the anti-static surface remains intact throughout the installation.
Step 4: Once the panels are in place, allow the floor to settle for at least 24 hours before use to ensure proper adhesion and performance.
Measuring tape and chalk line
Leveling tool to ensure flatness
Fasteners or adhesives recommended by the manufacturer
Utility knife for trimming panels (if necessary)
The Environmentally Friendly All-Steel Anti-Static Floor must be installed in a controlled environment. Temperature and humidity fluctuations can affect the performance of the flooring and interfere with the installation process.
Ideal Temperature: 18°C to 25°C (64°F - 77°F)
Humidity Level: 30% to 60% relative humidity is ideal for installation.
For optimal adhesion and performance, the surface must be prepared correctly. The surface should be:
Clean and free of dust, dirt, or oils.
Smooth and level; any bumps or depressions can affect the floor’s stability and alignment.
Dry and free from moisture. Excessive moisture can interfere with adhesion and cause the floor to warp.
Good ventilation during installation will help the adhesive or any curing materials used in the process to dry properly and prevent any potential issues related to moisture buildup.
Proper storage of the Environmentally Friendly All-Steel Anti-Static Floor is essential to maintaining its quality before installation. Here are the recommended storage guidelines:
| Storage Task | Instructions |
|---|---|
| Storage Location | Store panels in a cool, dry area, away from direct sunlight. |
| Stacking Panels | Stack panels flat on the ground and avoid placing heavy objects on top of them. |
| Avoid Moisture | Ensure that the storage area is dry and well-ventilated to prevent moisture buildup. |
| Temperature Control | Store in a temperature-controlled environment, ideally between 18°C and 25°C (64°F - 77°F). |
When handling the panels, take care to avoid scratching or damaging the surface. Use appropriate lifting techniques to prevent bending or damaging the panels during transportation and storage.
The Environmentally Friendly All-Steel Anti-Static Floor offers a combination of durability, eco-conscious design, and superior ESD protection. Whether you are setting up a new data center, upgrading your electronics manufacturing floor, or creating a clean room environment, this flooring solution provides the reliability and performance you need. By following proper installation guidelines, maintaining the floor regularly, and storing it in suitable conditions, you can ensure that it delivers long-lasting performance and helps maintain a safe, sustainable workspace.
Floor Finish: HPL1.2 / PVC2.0
Floor Uppon Thick:0.7mm
Floor Bottom Thick:0.6mm
Pedestal Uppon Size:75mm*75mm*3mm
Pedestal Bottom Size:95mm*95mm*2mm
Stringer Size:571mm*32mm*21mm*1mm
Screw Size:6mm*39mm
Single Weight:13kg
Floor ESD Resistance:106-109 ohm
| All-steel ESD Raised Floor | |||||||
| Model | Size (MM) | Concentrated Load | Distributed Load (N/㎡) | Ultimate Load (N) | Fire Resistance | ||
| LB | N | KG | |||||
| LP-450 | 600*600*30 | 500 | 1960 | 200 | 9720 | 5880 | B1 |
| LP-680 | 600*600*35 | 680 | 2950 | 300 | 12500 | 8850 | B1 |
| LP-800 | 600*600*35 | 800 | 3550 | 360 | 16000 | 10680 | B1 |
Product Description:
All-Steel ESD Raised Floor features an external layer of high-quality cold-rolled steel plate, treated with phosphating and electrostatic spray coating. The interior is filled with high-strength foamed cement for enhanced durability. The surface is covered with either high-wear-resistant, fireproof, and anti-static high-pressure laminate (HPL) or PVC board, with conductive edge strips applied around the perimeter.
This product has a wide range of applications, including data centers, computer rooms, monitoring rooms, production workshops, and other conventional single-room installations. Its tool-free disassembly design significantly reduces maintenance costs and simplifies the resolution of wiring-related issues.
Features:
1.Excellent anti-static performance, effectively reducing electrostatic-induced chain reactions
2.Tool-free disassembly for easier cable maintenance and lower upkeep costs
3.Optional matte surface for enhanced anti-slip effect
4.High resistance to pressure and extreme temperatures